Installation guide

Controller Installation (Standard)
2-14 AcceleRAID 150 Installation Guide
12. Enable termination power to all the disk drives (usually there is a
jumper on the drive). See your device documentation for instructions
on how to set your particular disk drives termination power and
configuration options.
Note
The supported SCSI drive types include Ultra2 SCSI
with LVD as well as the following single-ended SCSI
types: SCSI-1, Fast SCSI, Wide Fast SCSI, Ultra
SCSI, Wide Ultra SCSI, and Wide Ultra2 SCSI.
13. Safety check the installation by checking Pin 1 locations and cable
types. For more details, see step 3 in the section titled Before You
Begin (Standard) on page 2-2.
14. Replace the cover and connect the power cord.
The standard AcceleRAID 150 installation is complete.
Proceed to the next chapter for controller start-up procedures and other setup
options.