Installation guide

SCSI Drive Preparation
2-8 AcceleRAID Installation Guide
SCSI Drive Preparation
Prepare the drives for installation as follows:
Remove any terminators attached to the drive or set any drive
termination jumpers to the disabled position.
Set the SCSI addresses on the drives.
Note
Each drive must have a unique ID chosen from 0
through 6 or 8 through 15. ID 7 cannot be used as a
drive ID because it is reserved for the controller.
Enable termination power on the drives.
Refer to the drive manual for specific information about drive configuration
settings.
Note
The supported SCSI drive types include Ultra2 SCSI
with LVD as well as the following single-ended SCSI
types: SCSI-1, Fast SCSI, Wide Fast SCSI, Ultra
SCSI, Wide Ultra SCSI, and Wide Ultra2 SCSI.
m Caution
If wide drives are to be connected to a narrow SCSI
connector (by a 68-pin to 50-pin adapter), the 8-bit
bus width parameter must be set first, using RAID
EzAssist.
Instructions on how to force the 8-bit bus width are in
the RAID EzAssist Configuration Utility User
Reference Guide (P/N 775029), under “Advanced
Parameters.”