User guide

SPECIFICATION MYDATA SMD TOWER 513
SOFTWARE FUNCTION
STANDARD MODE MYLABEL MODE
2)
Nitrogen possible on request.
CASSETTES AVAILABLE
REEL WIDTH REEL DIAMETERS
4” - 7“ 13“
8 mm
12 mm
16 mm
24 mm
32 mm
1)
44 mm
1)
32 mm cassettes can alternatively house tray boxes.
1 Tray Box = 3 Trays (JEDEC)
Max. tray capacity = 504
Reel sizes 8 to 24 mm (4” / 100 mm reels)
8 to 24 mm (7” / 180 mm reels)
8 to 44 mm (13” / 330 mm reels)
Freely configurable and expandable
Access time 13 seconds
RANDOM ACCESS STORAGE SYSTEM FOR SMD REELS
CAPABILITY
CASSETTES
Component management
*
Stock monitoring
*
External communication protocol
User Access System
Traceability
Job preparation
*
Barcoding
*
Data Import / Export Function
*
Inventory Function
*
Component allocation
MYLabel integration
* Handled by MYLabel / MYPlan software.
SOFTWARE
STANDARD CONFIGURATION
REEL WIDTH CASSETTES / SMD TOWER REELS / CASSETTE NO OF REELS TOTAL
8 mm / 4” - 7“ 1 14 14
299
8 mm / 13“ 5 14 70
12 mm / 4” - 7“ 2 12 24
12 mm / 13“ 5 12 60
16 mm / 4” - 7“ 1 10 10
16 mm / 13“ 5 10 50
24 mm / 4” - 7“ 1 8 8
24 mm / 13“ 4 8 32
32 mm / 13“ 3 7 21
44 mm / 13“ 2 5 10
MAXIMUM REEL CAPACITY
REEL WIDTH CASSETTES / SMD TOWER REELS / CASSETTE NO OF REELS TOTAL
8 mm / 4” - 7“ 5 14 70
406
8 mm / 13“ 24 14 336
MAXIMUM TRAY CAPACITY
CASSETTE WIDTH CASSETTES / SMD TOWER TRAY BOXES / CASSETTE NO OF TRAY BOXES TOTAL
32 mm / 13“ 24 7 168 504
CASSETTE CAPACITY
CASSETTE TYPE NUMBER
4” - 7“ 5
13“ 24
CAPACITY
DRY AIR UNIT 2000 SUPERPLUS DL25
2)
Flow rate, max (in) 25 m
3
/h, (out) 19.75 m
3
/h
Flow rate, typ. 3 m
3
/h
Air supply class 4 (ISO 8573-1) or better
Operating overpressure (in) 6 - 16 bar
Medium temperature (in) 5 - 50°C
Power supply 110 / 230 V, 50/60 Hz, 7W
Dimension (W x D x H) 121 mm x 300 mm x 1377 mm (4,8“ x 11,8“ x 54,2“)
ACCESSORY