Owner manual
SPECIFICATION MYDATA SMD TOWER 2000
Reel sizes 8 to 24 mm (4” / 100 mm reels)
8 to 24 mm (7” / 180 mm reels)
8 to 44 mm (13” / 330 mm reels)
Freely configurable and expandable
Access time 15 seconds
RANDOM ACCESS STORAGE SYSTEM FOR SMD REELS
CAPABILITY
STANDARD CONFIGURATION
REEL WIDTH CASSETTES / SMD TOWER REELS / CASSETTE NO OF REELS TOTAL
8 mm / 4” - 7“ 21 14 294
562
8 mm / 13“ 5 14 70
12 mm / 4” - 7“ 3 12 36
12 mm / 13“ 3 12 36
16 mm / 4” - 7“ 4 10 40
16 mm / 13“ 2 10 20
24 mm / 4” - 7“ 2 8 16
24 mm / 13“ 3 8 24
32 mm / 13“ 3 7 21
44 mm / 13“ 1 5 5
56 mm / 13“ 0 4 0
MAXIMUM REEL CAPACITY
REEL WIDTH CASSETTES / SMD TOWER REELS / CASSETTE NO OF REELS TOTAL
8 mm / 4” - 7“ 30 14 420
658
8 mm / 13“ 17 14 238
MAXIMUM TRAY CAPACITY
CASSETTE WIDTH CASSETTES / SMD TOWER TRAY BOXES / CASSETTE NO OF TRAY BOXES TOTAL
32 mm / 13“ 17 7 119 357
CASSETTE CAPACITY
CASSETTE TYPE NUMBER
4” - 7“ 30
13“ 17
CAPACITY
CASSETTES AVAILABLE
REEL WIDTH REEL DIAMETERS
4” - 7“ 13“
8 mm • •
12 mm • •
16 mm • •
24 mm • •
32 mm
1)
•
44 mm •
56 mm •
1)
32 mm cassettes can alternatively house tray boxes.
1 Tray Box = 3 Trays (JEDEC)
CASSETTES
SOFTWARE FUNCTION
STANDARD MODE MYLABEL MODE
Component management •
*
Stock monitoring •
*
External communication protocol •
•
User Access System •
•
Traceability •
•
Job preparation •
*
Barcoding •
*
Data Import / Export Function •
*
Inventory Function •
*
Component allocation •
MYLabel integration
•
* Handled by MYLabel / MYPlan software.
SOFTWARE
2)
Nitrogen possible on request.
DRY AIR UNIT FREY FND 3.0 F-DP
Flow rate, max (in) 24 m
3
/h, (out) 20 m
3
/h
Flow rate, typ. 3 m
3
/h
Air supply class 4 (ISO 8573-1) or better
Operating pressure 5 - 10 bar
Power supply 115 / 230 V, 50/60 Hz, 18W
Dimension (W x D x H) 330 mm x 270 mm x 840 mm (13,0“ x 10,6“ x 33,1“)
ACCESSORY