Instruction Manual
- 4 -
Operation with AC120/240V-60Hz
Connect the appliance to a AC120/240V power source using the removable AC
cable supplied with the appliance.
In the Temperature window the temperature last set will flash for 5 seconds and then
automatically change to display the temperature inside the cabinet.
Press the “Up” or “Down” keys to set the temperature you require.
The set temperature will flash for 5 seconds and then automatically change to
display the temperature inside the cabinet.
To turn off the appliance, remove the plug from socket.
Operation with DC12V/DC24V
Connect the “DC cable supplied with the appliance to a suitable DC socket outlet .A
120 watt dc socket outlet is recommended. The appliance will automatically identify
and apply DC12V or DC24V.
The LED light “12V” (Noted: 12V and 120/240V share the same light) or “24V” will
illuminate to indicate the appliance is working.
In the Temperature window the digital temperature last set will flash for 5 seconds
and then automatically change to display the temperature inside the cabinet.
Press the “Up” or “Down” keystrokes to set the temperature you required.
The set temperature will flash for 5 seconds and then automatically change to
display the temperature inside the cabinet.
To turn off the appliance, remove the DC plug from the DC socket.
NOTE: When using 24V and 120/240V together, make sure to plug in 120/240V
power cord first then the 24V power cord. Otherwise the appliance will “BEEP”
indicating low voltage. This is not a malfunction.
CONTROL PANEL:
1 2 3 4 5 6 7
1. ON/OFF switch button