Operating instructions

- 25 -
Operation
Eject function
If button
j
M
is pressed instead of button
S
O
,
after inserting the measurement
Q
, the
backgauge will advance forwards so that
paper can be removed. Finally the backgauge
moves to the last setting.
Adjust the eject-dimension
Press
p
, hold, and press
T
e
on
display.
Insert the desired dimension.
(Standard is 20 cm).
g
Store dimension.
p
+
s
Escape the program mode.
Program buttons
b
and
j
programs
Press
p
, hold, and press
b
(
ö
appears on
the display) or
Press
p
, hold, and press
j
(
Ü
appears
on the display)
Enter the desired dimension (For example:
29,7 cm x 21 cm can be entered for DIN A4)
g
Store dimension.
Display in cm or inch
Press
i
display changes between cm
and inch (see page 22 and 24).
Cutting activation
Warning!
Run backgauge to the front for turning the
paper stack.
Do not interrupt the upward movement of the
blade by performing switching procedures.
Release blade only when LED "S"
X
has gone
out.
Close the front safety guard
A
.
Blade must always be at the top and be
covered by the clamp. Do not touch the
blade.
(see safety information on page 38).
Risk of injury!
Multiple cut
Enter the start dimension on the display
Q
.
Advance to the measurement with the
S
button.
Push the paper to the backgauge
I
.
Press
T
button the red LED "M "
Y
light
will be on.
Enter the multiple cut size.
After cutting has been activated press
S
button.
Every time the
S
button is pressed,
the
backgauge will advance by the multiple cut
size.
Pressing the
s
button
N
shows the actual
size.
Exiting program-mode
Pree
T
button LED "M "
Y
is cleared on
the display.