Owner`s manual
Page 25 
  Press 0 (OFF) to turn the selected room off (all lighting loads in the room are turned off). 
  Press 1 (ON) to turn the selected room on (all lighting loads in the room are turned on). 
  Press 2 (A) to set all of the lighting loads in the selected room to their preset levels for Scene A. 
  Press 3 (B) to set all of the lighting loads in the selected room to their preset levels for Scene B. 
  Press 4 (C) to set all of the lighting loads in the selected room to their preset levels for Scene C. 
  Press 5 (D) to set all of the lighting loads in the selected room to their preset levels for Scene D. 
  6 (SET) is not used with Vizia RF Z-Wave lighting. 
  Press # (STA) to view the current status of the room. 
Controlling Individual Lighting Loads in an Vizia RF Z-Wave Room 
To  control  individual  lighting  loads  in  a  room,  use  the  down  arrow  key  to  scroll  through  the  list  of  units.    When  the  unit  is 
displayed, press the ' # ' key. For Vizia RF Z-Wave lighting loads, the console will display: 
LR Sconce 
0=OFF 1=ON 2=DIM 3=BRT 
↓   
LR Sconce 
    4=LVL 5=RMP 9=TIM #=STA
↑ 
  Press 0 (OFF) to turn the selected lighting load off. 
  Press 1 (ON) to turn the selected lighting load on. 
  Press 2 (DIM) to dim the selected unit (1-9 steps, each step is 10% from its current level). 
  Press 3 (BRT) to brighten the selected unit (1-9 steps, each step is 10% from its current level). 
  Press 4 (LVL) to set the desired lighting level of the selected unit (0%-100%). 
  5 (RMP) is not used with Vizia RF Z-Wave lighting. 
  Press 9 (TIM) to time the selected unit (On, Off, Dim, Brighten). 
•  Timed commands may be from 1-99 seconds, 1-99 minutes or 1-18 hours. 
  Press # (STA) to see the status of the device. 
Note: When a Z-Wave signal is received over the network, OmniPro II will automatically update the status of the device. 
Controlling CentraLite Units 
Entry Lights 
0=OFF 1=ON 2=DIM 3=BRT 
↓!
Entry Lights 
4=LVL 5=RMP 9=TIM #=STA
↑ 
!
  Press 0 (OFF) to turn the selected unit off. 
  Press 1 (ON) to turn the selected unit on. 
  2 (DIM) does not affect CentraLite units. 
  3 (BRT) does not affect CentraLite units. 
  Press 4 (LVL) to set the desired lighting level of the selected unit (0%-100%). 
  5 (RMP) does not affect CentraLite units. 
  Press 9 (TIM) to time the selected unit (On or Off). Timed commands may be from 1-99 seconds, 1-99 minutes or 1-18 
hours. 
  Press # (STA) to see the status (On or Off) of a CentraLite device. 
WEB VERSION