Owner`s manual
Page 8 
What Happens When You Arm the Security System 
To arm the system into one of the 6 security modes, from the security menu, choose the security mode and press the appropriate 
key (1 - 6), and then enter your user code number on the console keypad or use one of the Shortcut Keys as described. 
  The console will beep once and the console LED will be set to red 
  The controller will cycle power to reset smoke detectors 
  The top line will display the security mode.  
  The bottom line will display, " *** ARMING SYSTEM *** " to indicate that the system is being armed. 
The system will be fully armed after the Exit Delay expires. 
If arming in Away or Vacation mode: 
  Consoles configured with Audible Exit Delay enabled, will beep until the Exit Delay has expired.  During the last 10 
second of the Exit Delay, the console will beep twice as fast; so leave and close the door promptly. 
  If enabled, “Exit Time Restart” will restart the exit delay if the same zone is violated twice within the original exit delay. 
For  example,  after  arming  the  system  if  you  open  the  front  door  to  leave,  close  the  front  door  behind  you,  and  then 
reenter through the front door while the exit delay is still in effect, the exit delay will be restarted.  This is designed to 
give  you  additional  time  to  exit  without  causing  an  alarm.    The  exit  time  will  only  be  restarted  once  within  a  given 
arming period. 
  If “Unvacated Premises” is enabled, if no exit zone is violated during the exit delay (i.e. the premises was not vacated), 
the system will automatically arm to Day mode at the expiration of the exit delay. 
NOTE: In Commercial Burglar Alarm Applications for UL Certified  Systems,  a  Ring-back  indication  and  Bell-test  should  be 
heard after arming (closing). If not heard, call for service. 
Exit Error 
The Exit Error feature is designed to prevent accidental alarms caused by an error while arming. If an entry-exit zone is  
“Not Ready” (unsecured) when the exit delay expires, the Exit Error sequence is initiated as follows: 
  The sounder(s) are activated 
  Console Entry Chime comes on 
  The console display indicates: " *** DISARM SYSTEM ***  - PRESS OFF THEN CODE" 
  The system will wait the Entry Delay time 
If the security system is not turned off during the Entry Delay: 
  The display shows the type of alarm and the violated zone:  "BURGLAR ALARM! - ZONE NAME TRIPPED" 
  The system waits the Dial Out Delay, then if configured, begins to dial out 
  The central station will be sent a code representing the type of alarm, zone violated, and an Exit Error code 
  The When Alarm macro is activated (any associated programs will be executed) 
  The Flash For Alarm Unit Number begins to flash on and off. 
Note: The Exit Error feature is incompatible with “Auto Bypass”. If enabled, Auto Bypass will override this feature. 
WEB VERSION










