Connecting Data Loops to Terminals on the Motherboard
D8125 POPEX modules must have their own data expansion loops:
The
motherboard provides two sets of D8125 POPEX Data Loops. POPIT modules assigned
to D8125 POPEX #1 cannot be placed on the D8125 POPEX #2 Data Loop. Limit the
Data Loops coming back to the motherboard to a maximum of four data loop runs for
each POPEX you install.
D8125 POPEX #1 D8125 POPEX #2
DATA LOOPS 1 TO 4 DATA LOOPS 5 TO 8
POINTS 9 - 71 POINTS 73 - 135
Wiring the POPIT Sensor Loop
POPIT modules monitor their sensor loops for three conditions, loop normal, loop open,
and loop shorted. They report these three conditions to the D9124 System.
The D9124 System uses point programming to interpret the sensor loop information
reported by the POPITs and make the appropriate system response.
Terminate all POPIT sensor loops with a 33k end-of-line resistor, Radionics Model
D106F, supplied with each POPIT module.