Installation manual
D9124 Operation & Installation Manual
Page 23
© 1996 Radionics
74-06799-000-D 2/96
D9112 Program Record Training Sheet for the D9124 System
The
D9112 Program Record Training Sheet for the D9124
(74-06802-000) presents an
example of a completed program record sheet for the D9124 System. The first column on
the program record sheet contains the address settings for the POPITs. Addresses are
numbered 1 to 6, left to right. Set addresses whose number appears in the ON position.
Set addresses with a dash (-) in the OFF position (see
Figure 12)
.
The second column contains the translation of the point number into the D8112 ZONEX
format. See
Point User Flag Point User Flag
in the
Panel Wide Parameters
module of the
D9112
Program Entry Guide
(74-06145-000) for an explanation of this feature.
The third column contains the point number as it is displayed at command centers. The
fourth column contains the point index. See the
Point Index Parameters
module in the
D9112 Program Entry Guide
(74-06145-000) for an explanation of the point index.
The fifth column of the record sheet shows the area the point is assigned to. The sixth
column shows the Debounce Count for the point. See
Debounce Count
in the
Point
Assignments
module in the
D9112 Program Entry Guide
(74-06145-000).
The seventh column shows the BFSK report code. It is the point number reported for this
point when the panel is using the BFSK format. The eighth column contains the text
displayed at command centers for the point. The text is transmitted to the receiver when
the panel is using the Modem II format.
Installing POPITs
Each POPIT comes with an installation card (79-02474-068). You should be familiar with
the POPIT Installation Card before attempting to install POPITS.
Routing the Data Cable
The two-wire data expansion loop connects POPIT modules assigned to a single D8125
POPEX. You can connect up to four data loops to one D8125 at the motherboard. Data
Loops 1-4 connect to D8125 POPEX #1. Data Loops 5-8 connect to D8125 POPEX #2
(see
Figure 8
).
Figure 12: Address Settings for POPITs
Point Assignments
Point Text
100
01
–– –– –– –– — —
——————————————
200
02
–– –– –– –– — —
——————————————
300
03
–– –– –– –– — —
——————————————
400
04
–– –– –– –– — —
——————————————
500
05
–– –– –– –– — —
——————————————
600
06
–– –– –– –– — —
——————————————
700
07
–– –– –– –– — —
——————————————
800
08
–– –– –– –– — —
——————————————
123456 101
09
–– –– –– –– — —
——————————————
1234 5- 102
10
–– –– –– –– — —
——————————— ———
1234 -6 103
11
–– –– –– –– — —
——————————————
BFSK/
T
ranslation Point Point Area Debounce Relay
# Index Assign
Popit
Address
Setting
11
11
INDICATIN G CKT
24V POWE R CKT 0