Instruction manual

9
Check the Control Panel Safety Checks
2-4 Check the Control Panel
Press the button.
- Press the button once and release.
- If the value of the current position of the back-
gauge decreases by 0.1 mm (0.005”), the
software is OK.
Press the button.
- If the value increases more than 0.1, then
decreases gradually and finally the value
increases by 0.1, the software is OK.
Because the screw has a little play,
when the backgauge is moved back-
ward, it is moved backward beyond the
input depth first, and then forward.
Continue to press the or
button.
- If the backgauge moves at low speed in the
arrow direction for three seconds, then it
moves at high speed, the software is OK.
Input 200 (mm) / 7.000 (inch).
- Check that the button is selected and
input the
keys (mm) /
the
keys (inch),
using the numeric keypad.
- If the backgauge moves and the value “200.0 /
7.00” appears in the box of the current posi-
tion of the backgauge, the software is OK.
When inputting the value 200, the input
of figures after the decimal point is not
necessary.
In the following steps, if the machine does
not operate as explained “the software is
OK”, stop the check immediately.
2 0 0
En
t
. 0 0
7
0
En
t