User Manual

15 LSS-Sh12
CV-Table
S = Default, L = Loco address, S = Switch address, LS = Loco and switch address usable
CV
Description
S
L/S
Range
Note
1
Loco address
3
L
1 127
if CV 29 Bit 5 = 0 (automatically reset)
7
Software version
read only (10 = 1.1)
7
Decoder reset functions
3 ranges available
11
16
33
basic settings (CV 1,11-13,17-19,29-119)
programming lock (CV 15/16)
switch outputs (from CV 120)
8
Manufacturer ID
160
read only
7+8
Register programming mode
Reg8 = CV-Address
Reg7 = CV-Value
CV 7/8 don’t changes his real value
CV 8 write first with cv-number, then CV 7
write with value or read
(e.g.: CV 49 should have 3)
CV 8 = 49, CV 7 = 3 writing
15
Programming lock (key)
215
LS
0 255
to lock only change this value
16
Programming lock (lock)
215
LS
0 255
changes in CV 16 will change CV 15
48
Switch address calculation
0
S
0/1
0 = Switch adress like norm
1 = Switch adress like Roco, Fleischmann
49
mXion configuration
6
S
bitwise programming
Bit
Value
OFF (Value 0)
ON
0
1
SW1 normal output
SW1 inverted
1
2
Transition normal switching
Transition fading
2
4
Transition same time fading
Transition after ones fading
3
8
Both red leds active (Sh0)
Only red1 active (Hp0)
4
16
SW2 normal output
SW2 inverted
5
32
normal function (RA12)
splitted, Hp0, Hp1, Hp2 (SW2)
6
64
do not save switch position
save switch position
7
128
normal function (RA12)
Hp0+Ra12 (DR-Pictures)
118
Automatic switch back function
to last state
0
S
0 255
0 = off
1 255 = time base 0,25 sec. each Value
120
SW1 address high
0
S
1 2048
switch signalstate, if address smaller 256
easy programm CV121 = desired address!
121
SW1 address low
1
S
122
SW1/SW2 dimming value
100
S
1 100
dimming value in % (1 % approx. 0,2 V)
125
SW2 address high
0
S
1 2048
active if CV49 Bit 5 = 1 or Bit 7 = 1
switch address for 3rd state (green/yellow)
126
SW2 address low
2
S