User Manual
16 BASIC-S
CV-Table
S = Default, A = Analog operation usable
CV
Description
S
A
Range
Note
1
Loco address
3
1 – 127
if CV 29 Bit 5 = 0 (automatically reset)
7
Software version
–
–
read only (10 = 1.0)
7
Decoder reset functions
2 ranges available
11
16
basic settings
programming lock (CV 15/16)
8
Manufacturer ID
160
–
read only
7+8
Register programming mode
Reg8 = CV-Address
Reg7 = CV-Value
CV 7/8 don’t changes his real value
CV 8 write first with cv-number, then CV 7
write with value or read
(e.g.: CV 49 should have 3)
CV 8 = 49, CV 7 = 3 writing
11
Analog timeout
30
30 – 255
1ms each value
15
Programming lock (key)
130
0 – 255
to lock only change this value
16
Programming lock (lock)
130
0 – 255
changes in CV 16 will change CV 15
17
Long loco address (high)
128
128 –
10239
activ only if CV 29 Bit 5 = 1
(automatically set if change CV 17/18)
18
Long loco address (low)
19
Traction address
0
1 –
127/255
loco address for multi traction
0 = deactive, +128 = invers
29
NMRA configuration
6
√
bitwise programming
Bit
Value
OFF (Value 0)
ON
1
2
14 speed steps
28/128 speed steps
2
4
only digital operation
digital + analog operation
5
32
short loco address (CV 1)
long loco address (CV 17/18)
7
128
loco address
switch address (from V. 1.1)
44
Clock divider
0
√
0 – 255
divides the clock through the CV value
48
Clock simulation correction
45
√
0 – 65
correction for simulated clock (1s /vale)
49
mXion configuration
12
√
bitwise programming
Bit
Value
OFF (Value 0)
ON
0
1
clock simulation
clock extern
1
2
extern clock normal
extern clock invers
2
4
poti deactive
poti active
3
8
steam not blending
steam blending