User manual

6
Modification reserved
19, rue de Rennes BP 83221 F - 35690 ACIGNÉ
1. SAFETY INSTRUCTIONS
1.1 SAFETY INSTRUCTIONS AND RECOMMENDATIONS
Only control the loader from the control station. Keep controlling until movements stop.
Do not leave the control station without stopping all control movements (control lever locked).
Never leave the tractor with the loader lifted. After using the loader, park the tractor with the loader lowered to the ground.
All persons must be kept away from the area in which the loader is moving while it is in operation. If any lifting
operations require the presence of a person near the load, the MX loader must be fitted with a safety device
(see the "SAFETY WHILE LIFTING AND DUMPING" section).
The operator must use an implement designed and recommended by MX for the work to be carried out.
Carrying or lifting persons using the loader is forbidden.
Ensure tractor stability by using a suitable counterweight (see the "COUNTERWEIGHT" section).
Restrict all movements with the load lifted as he tractor may become unbalanced.
The maximum front axle loading specified by the tractor manufacturer must not be exceeded.
In order to limit stresses on the front axle and steering ram, and to limit tyre wear, move forwards or backwards
when steering.
The maximum loading on the front tyres specified by the tyre manufacturer must not be exceeded.
Check tyre pressures regularly.
Check periodically to ensure that safety pins and bolts are in place. Do not replace them with any other items such as:
nails, wire, etc.
For full use of the MX loader, the tractor must be fitted with a falling object protective structure, or at the least a roll-over
protective structure with four uprights. If this is not the case, limit the use of the MX loader (see the "LOADER USE
LIMITS" section). Caution: the protective fitting must be in active position while working.
Watch out for overhead electricity and telephone lines, guttering, framework, etc. when moving with the loader in
raised position.
In compliance with standard EN 12525 + A2 2010, the controls for operating the loader and implements must be
"sustained action" type except for the floating position which can be held in place by a notching system.
Any fault diagnosis and/or removal of parts must be carried out by a professional who shall start by guaranteeing
that the work will be carried out safely for him and his environment, notably in the case of work on a lifted loader.