User Manual
© MuxLab Inc. HDMI 4x4 Matrix Switch Installation Guide
P
a
g
e 34
5.
Appendix
A. ASCII Command Set
Ensure that the terminal emulation program parameters
are set to the following:
BAUD Rate: 9600
Data bits: 8
Stop bits: 1
Parity: None
Flow control: None
It should be noted that commands are case sensitive and
arguments must be separated by a single space.
Characters that are not supported will be rejected by the
response: ILLEGAL CHARACTER. Commands must
be entered in the following way and ended with a
carriage return:
version
Description: Returns MuxLab product number & firmware version
Example: version
Arguments: [none]
Response: 500XXX Version Y.Y.Y
500XXX MuxLab part number
Y.Y.Y Firmware version
Example: 500415 Version 1.0.0