Serial/USB Port Commands
1. Alarm
alarm
Description: Display all the alarm settings
Arguments: <none>
Example: alarm
Response: Device Temperatures (Celsius):
- Temp min: 0
- Temp max: 70
Notification Method:
- Beep: ON
- Serial Port: ON
- Email: OFF
(or an error message if the command failed)
alarm -t <min value> <max value>
Description: Set the minimum and maximum temperatures value before an alarm is raised
Arguments: <min vallue>: 0 to 150
<max value>: 0 to 150
Example: Set the minimum and maximum temperature to respectively 5 and 70 degree Celsius, before an
alarm is raised
alarm –t 5 70
Response: Minimum and Maximum temperatures applied successfully!
(or an error message if the command failed)
alarm -n <method id> <state>
Description: Enable/disable a notification method.
Arguments: <method id>: b (beep), s (serial) or all
<state>: on or off
Example: Disable the beep notification method
alarm –n b off
Response: Alarm notifications applied successfully!
(or an error message if the command failed)