Instruction Manual
© MuxLab Inc. Audio 8x8 Matrix Switch Installation Guide
Page 38
10. Reset
reset -f
Description: Reset the unit and restore it to its factory settings
Arguments: <none>
Example: Reset unit and restore it to factory settings
reset -f
Response: “Clearing flash memory...
Rebooting...”
(or an error message if the command failed)
11. Sending Data
senddata –p <port #> -b <baud rate> -d “<data to send >“
Description: Send pass through data to a specific output port
Arguments: <port # >: 1 to 4
<baud rate>: 9600, 19200, 38400, 57600 or 115200
<data to send>: Hex string (max 80 characters)
Example: Send the following 4 bytes to port #3 0xA1, 0x55, 0xF2, and 0xC8
senddata –p 3 –b 9600 –d “A155F2C8”
Response: [“0304A1B2C3D4”]
Where:
03 = port number
04 = date length that follows (max value 0x28 bytes.)
A1B2C3D4 = data in hexadecimal (0xA1, 0XB2, 0xC3, 0xD4)
Command performed successfully
(or an error message if the command failed)