alarm -n <method id> <state>
Description: Enable/disable a notification method.
Arguments:
<method id>: b (beep), s (serial) or all
<state>: on or off
Example: Disable the beep notification method
alarm –n b off
Response: Alarm notifications applied successfully !
(or an error message if the command failed)
2. Connection
connect -i
<input port #> -o <output port #>
Description: Connect a specific input to a specific output
Arguments: <input port #>: 1 to 16
<output port #>: 1 to 16
Example: Connect input 5 to output 10
connect -i 5 -o 10
Response: [0,0,0,0,0,0,0,0,0,5,0,0,0,0,0,0]
(or an error message if the command failed)
connect -i <input port #> -o all
Description: Connect a specific input to all outputs
Arguments: <input port #>: 1 to 16
Example: Connect input 5 to all outputs
connect -i 5 -o all
Response: [5,5,5,5,5,5,5,5,5,5,5,5,5,5,5,5]
(or an error message if the command failed)
connect -i <input port #> -o <from output port #>..<to output port #>
Description: Connect a specific input to a consecutive range of outputs
Arguments: <input port #>: 1 to 16
<from output port #>: 1 to 16
<to output port #>: 1 to 16
<from output port #> shall be inferior or equal to <to output port #>
Example: Connect input 5 to outputs 8, 9, 10, 11, 12 and 13
connect -i 5 -o 8..13
Response: [0,0,0,0,0,0,0,5,5,5,5,5,5,0,0,0]
(or an error message if the command failed)
connect -json “[<input port #1>,<input port #2>,…, <output port #16>]”
Description: Make 16 connections/disconnections in one command using json format
Arguments:
<input port #>: 1 to 16 to specify the input port to connect to, or 0 to disconnect it
Example: Connect input 5 to outputs 8, 9, 10, and connect input 8 to outputs 1,2 , and disconnect all other
outputs.
connect -json “[8,8,0,0,0,0,0,5,5,5,0,0,0,0,0,0]”
Response: [8,8,0,0,0,0,0,5,5,5,0,0,0,0,0,0]