Installation guide

© MuxLab Inc. Multimedia 16x16 Matrix Switch Installation Guide
Page 44
Serial/USB Port Commands
1. Alarm
alarm
Description: Display all the alarm settings
Arguments:
<none>
Example: alarm
Response: Minimum Fan RPMs:
- Fan 1: 100
- Fan 2: 100
- Fan 3: 100
- Fan 4: 100
Device Temperatures (Celsius):
- Temp min: 0
- Temp max: 70
Notification Method:
- Beep: ON
- Serial Port: ON
- Email: OFF
Power supply: 1
(or an error message if the command failed)
alarm -f <fan # or all> <RPM value>
Description: Set the minimum RPM value for a fan(s) before an alarm is raised
Arguments:
<fan # or all>: 1, 2, 3, 4 or all
<RPM value>: 0 to 4999
Example: Set the minimum RPM to 150 for all fans before an alarm is raised
alarm –f all 150
Response: Minimum RPM value(s) for fan(s) applied successfully!
(or an error message if the command failed)
alarm -p <# of power supply>
Description: To indicate if the unit has 1 or 2 power supplies
Arguments: <# of power supply>: 1 or 2
Example: Indicate if the unit has 2 power supplies
alarm –p 2
Response: Power supply information saved successfully !
(or an error message if the command failed)
alarm -t <min value> <max value>
Description: Set the minimum and maximum temperatures value before an alarm is raised
Arguments:
<min vallue>: 0 to 150
<max value>: 0 to 150
Example: Set the minimum and maximum temperature to respectively 5 and 70 degree celsius, before an
alarm is raised
alarm –t 5 70
Response: Minimum and Maximum temperatures applied successfully !
(or an error message if the command failed)