User`s guide

Rockhopper II series printers – User’s Guide
84
AP-75095, Rev. 2.1, 18/08/2005
5.4.12. Thickness menu
Sets the media thickness.
* Thick *
50 µm – 1500 µm
+
F2
100 µm - F4
F2, F4
ENTER
Setup items
Parameters Description
Thickness 50µm-<100µm>-1500µm Change media thickness by operating the following
keys.
• [F2] key: to increase the setup value.
• [F4] key: to decrease the setup value.
• [ENTER] key: to confirm the setup value and to shift
to the previous hierarchy menu.
• [CANCEL] key: to cancel the setup value and to
shift to the previous hierarchy menu.
Refer to ‘User media menu’
5.4.13. Heater menu
Sets the temperature of the Heater.
* Heater (A) *
OFF – 50°C +
F2
50°C -
F4
F2, F4
ENTER
Use the [F2] or [F4] key to select the requested temperature for the Heater.
Notes :
The default setting for the heater is set to ‘50°C’.
The function of the heater (A) : Warming the transfer paper before entering the
pressure rollers. The pre-expansion helps to minimize media cockling.
Caution :
We recommend you to set the pre-heater temperature at 50°C. This to be sure that
transfer paper is already expanded a little before reaching the pressure rollers.