User`s guide

Rockhopper II series printers – User’s Guide
43
AP-75095, Rev. 2.1, 18/08/2005
3.5. INSTALLATION
Product installation is explained below.
3.5.1. Choosing a place for the printer
Install the unit on a proper location referring to the following.
Important :
Do not place the printer on a location under the following conditions. Doing
so may cause the product to fall, become damaged, or cause injury.
o
Unstable surfaces
o
Slanted surfaces
o
Locations that are subject to vibration from other product
Do not stand on the printer or place any heavy objects on it. Doing so may
cause it to fall over, become damaged, or cause injury.
Do not cover the ventilation hole of the printer with cloth, such as a blanket
or table cloth. Doing so could prevent the printer from ventilating and cause
fire.
Keep the printer away from humid and dusty areas. Humidity may result in
electrical shock or fire.
3.5.1.1. Installation environment Requirements
Choose a place for printer installation following the requirements in the table below.
50” model 11.7m² (133ft²) or larger. Frontage of 4.3m (14.3ft) or greater.
64” model 12.7m² (144ft²) or larger. Frontage of 4.7m (15.7ft) or greater.
Area
87” model 14.3m² (162ft²) or larger. Frontage of 5.3m (17.7ft) or greater.
Floor loading capability 2490Pa (300kg/m²) or over
Voltage AC100V - 120V or AC220V – 240V
Frequency 50/60Hz±1Hz
Electrical
Capacity AC100V - 120V: 12A or more
AC220V - 240V: 6A or more
Recommended
working environment
Temperature: 25°C
Humidity: 40% to 60%, without condensation
Operational conditions Temperature: 18°C to 35°C
Humidity: 40% to 60%, without condensation
Rate of change Temperature: No more than 2°C per hour
Humidity: No more than 5% per hour
Environmental
Storage environment Temperature: -20°C to 60°C
Humidity: 5 to 85%, without condensation (When ink has
been discharged.)
Notes :
Avoid the following temperature and humidity conditions. Otherwise, printed
images may appear differently from what you expect:
o Places where sudden changes in temperature and humidity are expected,
even though the condition is within the range written above.
o Places where direct sunlight or excessive lighting are expected.
o Places where air conditioners blow directly.
MUTOH recommends that the printer should be installed where air conditioning can
be adjusted easily.