4.8.4 Replacing the Y Paper Sensor Assembly
Step 1 : Remove the Front Cover. Refer to “Removing Front Cover”
Step 2 : Remove the Unit Panel Cover. Refer to “Removing Unit Panel Cover”
Step 3 : Remove the Y Rail Cover. Refer to “Removing Y Rail Cover”
Step 4 : Disconnect connector J204 (PEDGE) from the Head Board.
Step 5 : Remove the Head Cable keeper.
Step 6 : Remove the Paper Sensor.
Step 7 : To install removed components, reverse removal procedure.
Caution:
Be careful not to over-tighten when refitting the Waste Fluid Box Detector Switch
Assembly.