4.4.4. Replacing the Lever Sensor Assembly
Step 1 : Remove the Front Paper Guide. Refer to “Removing Front Paper Guide”
Step 2 : Remove the Unit Panel Cover. Refer to “Removing Unit Panel Cover”
Step 3 : Remove the Right Cover. Refer to “Removing Right Cover”
Step 4 : Open the Control Box. Refer to “Opening and Closing Control Box”
Step 5 : Disconnect connectors J104 (lever) from the Main Board.
Step 6 : Remove the Panel Cable Connector and Tube Guide (1 fastening screw) and disconnect
connector J301
Nr. Description
1 Connector J301
3 Tube guide
Step 7 : Remove the Panel Mounting Plate (2 fastening screws).
Step 8 : Open the two cable clamps, one attached to the front X reinforcement and one beneath the rear
felt.