AP-74038, Rev. 1.1, 25/01/05
Step 4 : Remove the Mother Board Assembly (4 fastening screws).
Step 5 : Remove the Main Board Assembly (5 fastening screws).
Step 6 : Assembling is the reverse of the removal procedure.
3.
Set DIP Switches
The DIP Switches on the Main Board Assembly are for board testing, not for making settings.
4.
Install the latest driver
Refer to “Installing a program”
5.
Install the backup parameters that were taken up in “1” in the new Main Board
Caution :
If backup parameters were not taken up in Step 1, enter them manually.
For the user setup list, refer to the section on “How to set parameters” in the Users
Guide and Functional Operation Edition.
Also, for adjustment parameters, refer to “Parameter Update”.
Replace the “Waste Fluid Box” if backup parameters were not taken up in Step 1.
The message [Change Tank?] will appear on the panel display. You should confirm
by answering ‘”YES”.