Specifications
Rockhopper 38 – Maintenance Manual
246
AP-74038, Rev. 1.1, 25/01/05
9.4.2 Error Messages
Error Description
Connect Error D1 sensor D1 has connection problem, please check connection
Connect Error D2 sensor D2 has connection problem, please check connection
Connect Error A1 sensor A1 has connection problem, please check connection
Connect Error A2 sensor A2 has connection problem, please check connection
Front Strip>65°C heater strip D has too high temperature
Fixer Strip>85°C heater strip A has too high temperature
Group Front Err sensor group D error, >20°C difference between sensors D1 and D2
Group Fixer Err sensor group A error, >20°C difference between sensors A1 and A2
Front strip err heater strip D has connection problem, please check the fuse
Fixer strip err heater strip A has connection problem, please check the fuse
Front Fail Heat heater strip D failed to reach target temperature within 10 min
Fixer Fail Heat heater strip A failed to reach target temperature within 10 min
Front SSR Error heater strip D has solid state relay problem
Fixer SSR Error heater strip A has solid state relay problem
Both SSR Error heater strips A & D have SSR problem
AC Not Present
Please Check AC
No AC present
Strips Testing
Could Not Be Run
Please Check
Sensors Connect
one or more of sensors disconnect