Specifications

Rockhopper 38 – Maintenance Manual
243
AP-74038, Rev. 1.1, 25/01/05
No Message Checkpoint Action
1.1 • Check inside the waste fluid
box. If it is full of ink, explain to
the customer as you replace the
waste fluid box.
1.2 • Use the self-diagnostic "Sensor:
No Ink" to check the cartridge that
has no ink.
Remove all cartridges and check
that the "No Ink" display changes
when you gently press the black
plastic switches of the detector
assemblies (K, C, M and Y) on and
off.
1.3 • Use the printer's self-diagnostic
"Sensor: Box Exist/Box is not" to
make sure that the waste fluid
box
detection is working normally.
Slowly remove and replace the
waste fluid box to confirm that the
present/absent display appears.
If the display is not normal, the
sensor mounting position may be at
fault.
Remove the R Cover and adjust the
mounting position of the waste fluid
box detection switch assembly.
1.4 • Check the waste fluid box
detection switch contact. J105
(INK TANK) on the main board
Insert it correctly.
Replace it.
1.5 • Is the waste fluid tube from the
flushing box kinked?
Fix it and attach it again.
2.1 • Is the flushing box choked with
trash?
Remove the trash.
Replace it.
2.2 • The extension tube under the
pump assembly may have come
away.
Remove the maintenance station
GA assembly and check whether the
extension tube has come away.
Replace the pump assembly.
Replace the pump motor
assembly.
Replace the cap assembly.
1
2
3
• Ink has overflowed
from the waste fluid
Box
• Ink overflows from
flushing box
• Ink is spilt around
the X rail
3.1