9.3 ERRORS WHEN MESSAGE IS NOT DISPLAYED
9.3.1 Trouble with Initialization.
No Message Explanation Checkpoint Action
1.1 • Is there a broken or shorted lead
in the switch cable assy (between
the switch and
power supply board)?
Use a tester to check for broken or
shorted leads.
Replace the switch cable
assy.
1.2 • Do the "Power supply voltage
check 100 V AC"
1.3 • Do the "Power supply voltage
check 5 V DC"
1.4 • Do the "Power supply voltage
check 24, 42 V DC"
1.5 • Check the panel cable
connectors on the panel board
and main board.
Are they inserted obliquely?
Are they securely locked?
Check Main board J110 (PANEL),
panel board J301 (MAIN)
Reconnect the
connectors.
1.6 • The panel cable may be faulty.
Replace it.
1.7 • Is there a fault in the panel board
assy liquid crystal display?
Replace the panel board
assy.
1 No Power
Faulty LCD
(no display,
unstable
display)
1.8 • The main board assy may be
damaged.
Replace it.