Specifications
Rockhopper 38 – Maintenance Manual
199
AP-74038, Rev. 1.1, 25/01/05
9.2.3 Command Errors
No Message Explanation N° Checkpoint Action
1.1 • Try communicating with
the available computer and
cable.
• Confirm: Does the error
occur when the RS-232C
cable is changed?
→ Contact your Mutoh local
dealer.
→ There may be a broken signal
lead in the RS-232C cable or the
cable itself may be too long for
good communication.
→ Advise the use of a cable that
gives good communication.
1.2 Is there any record of an
error in the printing data?
→ Try changing the type of
application driver.
1.3 • If the symptoms persist
despite various application
driver changes
→ Obtain the printing data
Report to your local Mutoh
dealer after you have obtained it
1 MH01 Error
(undefined
command)
MH02 Error
(Parameter
Error)
MH03 Error
(Numerical
Error)
MH04 Error
(Undefined
Character
Set)
MH07 Error
(Buffer
Overflow)
A command that is
not defined in any
command mode
has been
analyzed
Wrong number of
parameters
following the
command
Wrong number of
parameters
following the
command
A nonexistent
character set is
present
The polygon buffer
or the download-
able character
buffer has
overflowed.
1.4 • The main board assy may
be damaged.
→ Replace it.