Specifications

Rockhopper 38 – Maintenance Manual
134
AP-74038, Rev. 1.1, 25/01/05
5.4.12 How to Adjust the Rear Sensor Position
This procedure is used to ensure the proper detection of the length of cut sheet media. It adjusts the position
of the rear sensor in the firmware by entering the media length after cut media has been
loaded and
detected. This item is essential in the production process but it is no longer necessary once media feed
distance compensation has been carried out. When this item is selected, whether media is loaded or not, it
will ask for cut sheet media. If panel diagnosis decides that media is loaded, this will be assumed to be cut
sheet media and media initialization will begin. Therefore roll media should not be loaded. After the media
has been initialized, it will be ejected. To terminate this program without updating the setting, press the
[Back] or [ESC] key while no processing is in progress.
Press [ENTER] to update the setting, and move to “AJST: Test Print”.