Specifications
Rockhopper 38 – Maintenance Manual
114
AP-74038, Rev. 1.1, 25/01/05
5.2 PREPARATION
Before you can use the self-diagnostic function, you should make the machine ready and display the self-
diagnosis menu.
5.2.1 Preparation on machine
Before starting up the self-diagnosis function, perform following preparations.
(1)
Setting printing media
Notes :
The system will not revert to normal mode even if there is no key entry for three
minutes.
Roll media is set automatically.
Panel keys that can be operated are [CANCEL] and the keys for menu display
(Menu Up and Down, Back, Value+ and -, ENTER)
To terminate self-diagnostics, switch off the power.
To feed media, press [MENU] while holding down the [Shift] key when the
Diagnostics Menu is displayed.
(2)
Connecting power cable
Connect the power cable to the machine’s inlet assembly and insert the plug into the outlet.
Notes :
Do not connect three or more power plugs to the outlet.
5.2.2 Starting up
To use the self-diagnosis function, you should first display the self-diagnosis menu on the operation panel.
The self-diagnosis menu is completely independent of the normal operation mode and self-diagnosis display
mode. To call up the self-diagnosis menu, follow the steps below.
Step 1 : If the system is in the operation mode or the self-diagnosis menu mode, press the [POWER] key
to power off the unit.
The power is turned off.
Step 2 : Press and hold the [Head Cleaning] key, [Menu Display] key, and [Shift] key simultaneously.
While holding down these keys, press the [POWER] key.
The system will enter the self-diagnosis mode and display the self-diagnosis menu.