4.2.2 Adjustment
Depending on the result of the calibration (as described in the previous chapter), the scroller bar should be
adjusted until it is positioned horizontally to obtain a straight winding flow.
Follow the procedure below to adjust the scroller bar.
Step 1 : Evaluate on basis of the drawn lines how the bar is positioned compared to the print platform.
Situation 1 Situation 2
Line 1 = left side calibration line
Line 2 = right side calibration line
Line 1 = left side calibration line
Line 2 = right side calibration line
In this situation, the right side of the scroller bar is
higher than the left side.
In this situation, the left side of the scroller bar is higher
than the right side.
Higher the left side of the scroller bar with the
adjustment screw.
Lower the left side of the scroller bar with the adjustment
screw.
Step 2 : Lower or higher the left side of the scroller bar as follows:
a. Loosen the fixation screw (1).
b. Higher or lower the scroller bar with the adjustment screw (2).
c. Tighten the fixation screw again.
Step 3 : Verify the adjustment by following the calibration procedure once again.