5.2.2 NozzleCheck
If printing quality declines, or if missing dots are evident after the NozzleCheck, the print heads need to be
cleaned. Refer to Head cleaning" to perform head cleaning. After finishing the head cleaning, wait for 10
minutes and perform the NozzleCheck again.
Use this function to check if there is any clogging of nozzles, missing dots or faint printing.
Notes
Make use of the blue light to evaluate the yellow nozzles. The switch for this light can be found
here:
Following pattern will be printed. The numbers above the NozzleCheck represent the heads. In case there
are some missing nozzles, it is possible to clean the head separately. Please refer to the Cleaning Menu.