4.14 SERVICE DONE BY AUTHORISED MUTOH TECHNICIAN
This section describes the periodical services which should ONLY be done by an Authorised Mutoh
Technician.
Perform periodical inspections according to the table below.
Action Frequency
13 Change absorbent in maintenance station
6 monthly
14 Change dampers
15 Change waste tubing from collector > waste bottle
16 Change spitting box + tube + L connection
17 Apply grease on head up-down cams
18 Apply grease on Y-motor belt
19 Apply grease on roller path carriage
20 Apply grease on capping station cams+ gears
21 Change cap assembly maintenance station After 6 months
22 Change maintenance station
Yearly
23 Change wiper arm assembly and wipers
Notes
All cleaning in Ink areas must be done with Mutoh solvent cleaning solution.
Above maintenance cycle is based on use:
8 hours / day, 5 days / week, 44 weeks / year.
If machine is used more, maintenance periods will come earlier.
Please refer to the latest spare part price list for the part numbers of the maintenance kits.