User`s guide
Spitfire 100 Extreme series printers Users Guide
20 AP-75194 - Rev. 2.2
2.1.3 Heater system
Heater Element Temperature Function
Pre-heater (Heater A) 20 50°C
Open the pores to make the media more receptive for Spitfire
Mild Solvent series Ink.
Fixer (Heater B)
20 40°C
(for MS - MS
Plus)
20-70°C
(for Eco)
To establish optimum fixation onto the media (coated and
uncoated).
Optimizes the dot gain control.
Post-Fixer (Heater C) 20 70°C
The post-fixer finalizes the fixation process and helps to
make the prints touch-dry.
Dryer (Heater D) 20 50°C
The dryer completes the drying for compatibility with the
take-up in combination with higher output speeds.
There have been a number of requests from the field, asking the heaters to be on by default for a few user
settings. This has now been implemented as follows:
For user 1 and user 8 default settings are as follows:
a. Pre heater A: 50°C
b. Fixer B: 40°C
c. Post Fixer C: 50°C
d. Dryer D: 50°C
For users 2 7, by default the heaters are still OFF.
Notes
Please note some RIP software do not allow selection of the user from software side. In some
cases, however, they do automatically activate user 8