2.3 INSTALLATION REQUIREMENTS
2.3.1 Installation environment requirements
Choose a place for printer installation following the requirements in the table below.
Area
65 model 12.7m² (144ft²) or larger. Frontage of 4.7m (15.7ft) or greater.
90 model 14.3m² (162ft²) or larger. Frontage of 5.3m (17.7ft) or greater.
Floor loading capability 2940 Pa (300kg/m²) or over
Electrical
Voltage
AC 100-120V
AC 220-240V
Frequency 60/50Hz±1Hz
Capacity
AC100V-120V : 12A
AC220V-240V : 6A
In order to protect the printer for over currents, short circuits and earth faults, equip the building
installation with an automatic breaker double pole of 20 A and an earth leakage switch of 300 mA.
Environmental
Recommended
working
environment
Temperature: 25°
Humidity: 30% to 60%, without condensation
Operational
conditions
Temperature: 19° to 26°
Humidity: 30% to 60%, without condensation
Rate of change
Temperature: No more than 2° per hour
Humidity: No more than 5% per hour
Storage
environment
Temperature: -20° to 60°
Humidity: 5 to 85%, without condensation (When ink has been
discharged.)
2.3.2 Required space
Install the product on a flat surface that fulfils the following conditions.
a = 1,5 m
b = 1,5 m
c = 2,5 m
d = 0,6 m
e = 1,3 m