Specifications
Maintenance Manual – SC Cutting Plotter
44 AP-74030, Rev / B
Pen Force : 40 g
F2 change : DOWN
Press ENTER to
Input value
F2 (F2) toggles pen UP/DOWN.
Attach bar tension gauge of 50g to pen and read the value
when the pen tip lifts from the paper.
Press F2 (DOWN)
Press ENTER
F1
F3
* Pen Force Input *
1g ® 40g
F2
F4
F1/F3 changes the digit
F2/F4 changes the value.
Enter the measured value
Press ENTER
Pen Force : 450g
F2 change : DOWN
Press ENTER to
Input value
F2
(F2) toggles pen UP/DOWN
Attach a bar tension gauge of 500 g to pen and read the
Press F2down
Press ENTER
value when the pen tip lifts from the paper.
F1
F3
Pen Force Input
1g ® 450g
F2
F4
F1/F3 changes the digit
F2/F4 changes the value.
Enter the measured value
Press ENTER
Confirm Input
40 ® 40 , 450 ® 450
Press Enter
Press ENTER
Press ENTER
2) Pen force Verify.
F3
* Pen Force *
Plot
Adjustment Check
F2
F4
(F2) Plot is of no importance
(F4) to verify the pen force calibration.
Press F4
Put Pen in the
Head Close cover
and press ENTER
Put adjustment pen JD-41440 in penhead.
Press ENTER
F1
F3
Pen Force :
10g : DOWN
DOWN / UP
F2
F4
With F1/F3 you can select different pen forces.
With F4 you can toggle UP/DOWN.
Attach a bar tension gauge to the pen and verify the value.
Press EXIT, Press ENTER.