Specifications

Maintenance Manual – SC Cutting Plotter
43 AP-74030, Rev / B
Caution :
You cannot check if the calibration is correct by internal test from the plotter.
Check the calibration by sending a file from the computer.
If you perform the 500mm (20Inch) square again, it will be plotted as before
WITHOUT calibration.
2) Cutting mat height calibration (roller).
This test measures unevenness of the cutting mat on ± every 40 mm and stores this data in
EEPROM. This data is used to compensate the pen height on this particular places.
F3
* Adjust – 08 *
Xaxisadj Roller
F4
Without paper loaded, put the Special Adjustment pen
Press F4
JD-41440 in the penholder.
Press (F4) Roller.
Press (F3) Measure.
F3
* Roll height *
Measure Display
F4
Press ENTER to start the test.
The plotter starts to measure the cutting mat height on
every ± 40mm.
Press ENTER to save data.
Note :
It is recommended to performed the cutting mat height calibration after
replacement of the cutting mat.
(F4) Display is of no importance.
5.3.9. Adjust. 9
1) Pen force calibration.
F3
* Adjust – 09 *
PenForce Cutter
F4
Press F3
F3
* Pen Force *
Plot
Adjustment Check
F2
F4
(F2) Plot is of no importance.
Press F3
For Pen Force adjustment
Put Pen in the head
Close cover and press
ENTER.
Put Adjustment pen JD-41440 in penhead.
Press ENTER