5.4.3 EPOS calibration
This test will fine-tune the position of the cutting knife compared to the EPOS laser firmware wisely. This test
can be done manually and automatically. It is recommended however, to let the SC-Pro adjust the values
automatically.
Step 1 : Install and set a knife.
Step 2 : Install a dark (black) vinyl. Check with the EPOS readout function if it is dark enough as
described in the previous chapter.
Step 3 : Press the [TEST]-key.
Step 4 : Select “EPOS calibration” with the - keys.
Test
EPOS calibrate
METHOD: <TEST>
To start:
Step 5 : Press the [TEST]-key once again to decide whether to perform the test automatically or manually.
EPOS calibrate
Manual
30 cm/s 120 g
To start:
Step 6 : Move the cutter head with the arrow keys to the centre of the media and feed it a bit to be sure
you have enough space (10 cm x 10 cm) for the test.
Step 7 : Press the [ ] key to start the calibration.
►
MANUAL CALIBRATION
o Be sure that you have set an origin.
o Following pattern will be cut: