Specifications

Rockhopper II series printers – Maintenance Manual
61
AP-74065, Rev. 1.2, 27/09/04
Step 9 : Stick onto the sensor a sensor insul. patch.
1 = sensor insul. patch 2 = assembly hole
Step 10 : Reinstall all parts in the opposite order of the removal procedure.
Notes :
¾ During reinstallation of the plate, make sure there are no cables stuck.
4.3.2.3. Replacing the fixer (Heater B1 and Heater B2) on a Rockhopper II 4H printer
Before replacing the fixer, make sure to have following items:
¾ 50” model : Fixer B1 50 and Fixer B2 50
¾ 64” model : Fixer B1 64 and Fixer B2 64
¾ 87” model : Fixer B1 87 and Fixer B2 87
¾ Isolation tape
¾ Plot platform calibre
To replace the fixer on a Rockhopper II 4H printer, please follow the instructions mentioned below.
Step 1 : Remove side cover L.
Step 2 : Remove side cover R.
Step 3 : Remove the front cover.
Step 4 : Remove the Y rail cover.
Step 5 : Remove the front paper guide.
Step 6 : Place the plot platform calibre onto the plot platforms.
1 = plot platforms 2 = plot platform calibre onto the plot platforms