Specifications

Rockhopper II series printers – Maintenance Manual
35
AP-74065, Rev. 1.2, 27/09/04
3.4. INSTALLATION
The Installation of the unit is explained below.
3.4.1. Conditions of the installation environment
Important :
Do not place the printer in following areas. Doing so may result in the printer
falling over and causing injury.
Unstable surfaces
Slanted place
Where vibration of other machines is transmitted.
Do not sit on the printer or put heavy things on the printer. Doing so may cause
the printer to fall and injure people.
Do not cover the ventilation hole of the printer with cloth, such as a blanket or
table cloth. Doing so could obstruct ventilation and cause fire.
Do not place the printer in humid and dusty areas. Doing so may result in
electrical shock or fire.
(1) Conditions of the installation environment
Select the place to install this unit according to the environmental condition in the table below.
50” model 11.7 m² or larger. Frontage of 4.3 m or greater.
64” model 12.7 m² or larger. Frontage of 4.7 m or greater.
Area
87” model 14.3 m² or larger. Frontage of 5.3 m or greater.
Floor loading capability 2490Pa (300kg/m²) or over
Voltage AC100V - 120V or AC220V – 240V
Frequency 50/60Hz±1Hz
Electrical
Capacity AC100V - 120V: 3A or more
AC220V - 240V: 1.5A or more
Recommended
working environment
Temperature: 25°C
Humidity: 40% to 60%, without condensation
Operational conditions Temperature: 18°C to 35°C
Humidity: 40% to 60%, without condensation
Rate of change Temperature: No more than 2°C per hour
Humidity: No more than 5% per hour
Environmental
Storage environment Temperature: -20°C to 60°C
Humidity: 5 to 85%, without condensation (When ink has
been discharged.)