Specifications

Rockhopper II series printers – Maintenance Manual
283
AP-74065, Rev. 1.2, 27/09/04
4 E071 error PF
over current
An overload
occurred in the PF
motor (X-axis)
during operation.
(4) PF motor
assembly may be
damaged.
(5) Mainboard
assembly may be
damaged.
• Replace PF
motor assembly
• Replace
Mainboard
assembly
Replacing PF
Motor Assembly
Replacing the
Mainboard
assembly,
HDD_Extension
board assembly,
HEAD_DRV
board assembly
and cooling fan
assembly.
5 E 066 Error
CR Motor
Trouble occurred in
the CF motor (Y-
axis) during
operation.
Displayed when the
motor commanded
value and feedback
from the encoder
are significantly
different.
(1) Check the
trouble history via
“Test: Record” of
the self-diagnostic
function
-
History Menu
6 E 068 Error
CR Encoder
Trouble occurred in
the head travel (Y-
axis) during
operation.
Displayed when
there is no feedback
from the encoder.
(2) With the power
supply off, move
the carriage side to
side to check for
jamming.
Refer to Error
E072
• Clean and
lubricate the rollers
of the CR rail.
Lubrication /
Bonding
7 E 070 Error
CR Timeout
Err
Time out occurred in
the head travel (Y-
axis) during
operation.
Displayed when he
carriage has not
reached the
commanded
position.
(3) Check if “CR
Motor Error”
occurs by setting
the durability
cycles at 50 over
larger via “Life: CR
Motor” of the self-
diagnostic
function.
• Check he
connections of the
following
connectors.
Mainboard
assembly
• CR motor
assembly
connector : J158
• CR tape power
cable connectors :
J137 – J152
CR Board
assembly
• CR tape power
cable connectors :
J201 – J216
• CR_ENC
assembly
connector : J233
Replacing the
Mainboard
assembly,
HDD_Extension
board assembly,
HEAD_DRV
board assembly
and cooling fan
assembly.