Specifications
Rockhopper II series printers – Maintenance Manual
237
AP-74065, Rev. 1.2, 27/09/04
(1) HIGH level (with media) adjustment of the A/D value
Step 1 : Set the standard media.
Step 2 : Select "Check : Head Lock" in the self-diagnosis menu.
Notes :
¾ Refer to “Self-Diagnosis Function ".
Step 3 : Release the head lock.
Step 4 : Check if the installation angle of the P_EDGE sensor is 15°.
Step 5 : In the inspection menu, select "Check : Check".
Step 6 : Display "Sensor : PaperEdgeAD".
Step 7 : Open the front cover.
Step 8 : Move the carriage so that the dimension between the right edge of the standard media and the
cutter is 5 to 10 cm.
1 = Razor Blade 2 = Carriage
Step 9 : Adjust the P_EDGE sensor control shown in the following figure so that the values displayed in
the operation panel become the adjustment value.
¾ Control R693: Rough adjustment
¾ Control R694: Fine adjustment
1 = Volume R693 2 = Volume R694