Specifications
Rockhopper II series printers – Maintenance Manual
197
AP-74065, Rev. 1.2, 27/09/04
5.11. HEATER SYSTEM MENU
This section describes the heater system menu.
This menu is used to evaluate the heating elements of the printer.
Initialization item Description Refer to
Status This menu displays the status of the heating system.
→ Heater Status Menu
Temperature This menu displays the real temperature of the heating
elements.
→ Heater Temperature
Menu
Test 30 This menu heats the temperature up to 30°C.
→ Heater Test 30 Menu
Test 50 This menu heats the temperature up to 50°C.
→ Heater Test 50 Menu
Test Max This menu heats the temperature up to the maximum
temperature.
→ Heater Test Max Menu
Version This menu displays the version of the control heater
board.
→ Heater Version Menu
Adjust For calibration of the heaters.
For future use only!
→ Heater Adjust Menu
* Heating System *
F1 →
Status Temperature
← F2
F3 →
Test 30 Test 50
← F4
(1/2)
* Heating System *
F1 →
Test Max Version
← F2
F3 →
Adjust
(2/2)
5.11.1. Heater Status Menu
This menu displays the status of the heating system.
* Status *
Heater Standby
No errors
5.11.2. Heater Temperature Menu
This menu displays the real temperature of the heating elements.
* Temperature *
A : R25
B1 : R24 B2 : R24 C : R25
D1 : R26 D2 : R26