Specifications
Rockhopper II series printers – Maintenance Manual
190
AP-74065, Rev. 1.2, 27/09/04
5.9.5. Head Lock Endurance menu
Test endurance of head lock.
In the Head Lock Endurance menu, you can perform head lock operation according to the set items.
Notes :
Refer to "Head Up/Down Endurance Menu"
The wait time for head lock endurance is set to 10 seconds.
* Head lock *
Wiper U/D Yes/No + Wiper up and down
Yes -
↓ ENTER
* LifeCount *
Count
-1 → 10000 +
Number of endurance running cycles
50 -
↓ ENTER
* Head Lock *
Time Wait (sec) 10 Check wait time
↓ ENTER to perform endurance
* Head Lock *
Count 5 Perform endurance running
↓ End
* Head Lock *
End 50