User`s guide
User’s Guide Rockhopper 3 Extreme
CHAPTER 6 : PRINTER MENU
88 AP-75198– Rev. 1.2
6 .5.1.10 Th icknessm enu
Set the media thickness.
Setup items Parameters Description
Thickness 50µm-<100µm>1500µm Change media thickness by operating the following keys.
[F2] key: to increase the setup value.
[F4] key: to decrease the setup value.
[ENTER] key: to confirm the setup value
[CANCEL] key: to cancel the setup value
Notes
Bidirectional quality can only be obtained when media thickness is set correctly
6 .5.1.11 H ea term enu
Set the temperature of the Heater.
Setup items Parameters Description
Heater OFF 50°C Change heater temperature by operating the following keys.
[F2] key: to increase the setup value.
[F4] key: to decrease the setup value.
[ENTER] key: to confirm the setup value
[CANCEL] key: to cancel the setup value
Notes
The default setting for the heater is set to 50°C.
The function of the heater (A): Warming the transfer paper before entering the pressure rollers. The
pre-expansion helps to minimize media cockling.
6 .5.1.12 F ixerm enu
Set the temperature of the Fixer.
Setup items Parameters Description
Fixer OFF 40°C Change fixer temperature by operating the following keys.
[F2] key: to increase the setup value.
[F4] key: to decrease the setup value.
[ENTER] key: to confirm the setup value
[CANCEL] key: to cancel the setup value