2.4 INSTALLATION ENVIRONMENT
An Authorized Mutoh technician will install your unit and will make the printer ready for its first job. A room
which meets the environmental and space conditions should be foreseen by the user.
Important
Do not place the printer on a location under the following conditions. Doing so may cause the
product to fall, become damaged, or cause injury.
Unstable surfaces
Slanted surfaces
Locations that are subject to vibration from other product
Do not stand on the printer or place any heavy objects on it. Doing so may cause it to fall over,
become damaged, or cause injury.
Do not cover the ventilation hole of the printer with cloth, such as a blanket or table cloth.
Doing so could prevent the printer from ventilating and cause fire.
Keep the printer away from humid and dusty areas. Humidity may result in electrical shock or
fire.
2.4.1 Environment
Area 65 model 12.7m² (144ft²) or larger. Frontage of 4.7m (15.7ft) or greater.
90 model 14.3m² (162ft²) or larger. Frontage of 5.3m (17.7ft) or greater.
Floor loading capability 2940Pa (300kg/m²) or more
65 90
Electrical Voltage AC 100-120V
AC 220-240V
AC 100-120V
AC 220-240V
Frequency 60/50Hz 60/50Hz
Capacity AC100V-120V : 12 A
AC220V-240V : 6 A
AC100V-120V : 13 A
AC220V-240V : 7 A
In order to protect the printer for over currents, short circuits and earth faults, the building
installation should be equipped with an automatic breaker double pole of 20 A and an earth
leakage switch of 300 mA.
Ambient
conditions
Recommended
working
environment
Temperature: 23°C
Humidity: 55%, without condensation
Operational
conditions eco-
solvent ultra ink
Temperature: 20°C - 30°C
Humidity: 40% to 65%, without condensation
Rate of change
Temperature: No more than 2°C per hour
Humidity: No more than 5% per hour
Storage and
transport conditions
Temperature: 4°C to 50°C
Humidity: 40 to 80%, without condensation (When ink has been
discharged.)