Instruction manual

Operation Instructions Rockhopper 3 Extreme
CHAPTER 4 : PERIODICAL MAINTENANCE
35
4.1.3 Every 6 months maintenance
4.1.3.1 Change upper sponge at back of the capping station.
Step 1 : Go to the WiperClean menu and DON’T press enter when in it.
Going to the WiperClean menu will unlock the head
Step 2 : Remove the two screws fixing the sponge (1).
1 = Screws fixing the sponge (1)
Step 3 : Replace the sponge and tighten it again to the plate with the two screws.
1 = Capping sponge
2 = Plate
Step 4 : Close the front cover and press the [ENTER] key in the active display (=WiperClean menu)
The head will cap in and be locked.