Specifications

3 Specifications PJ-1614NXE PJ-2216NXE Maintenance Manual
3-8
3.5 Conditions of the installation environment
WARNING
Do not install the printer at any of the following places. Doing so may cause
the printer fall and injure people
Slanted place
Where vibration of other machines is transmitted.
Do not sit on the printer or put heavy things on the printer. Doing so may
cause the printer fall and injure people.
Do not cover the printer with something like a blanket or a table cloth. That
may cover the ventilation hole, confine the heat inside of the printer and cause
fire.
Do not install the printer in a damp or dusty place. Doing so may cause electric
shock or fire.
(1) Conditions of the installation environment
Select the place to install the printer in accordance with "3-1 Conditions of the installation environment".
Table 3-1 Conditions of the installation environment
Installation area
5m
2
or more, 2.6m or more is required for the width
Floor strength of the installation place
2490Pa (300kgf/m
2
) or more
Power
specifications
Voltage AC 100V to 120V±10%
Frequency 50/60Hz±1Hz
Capacity 10A or more
Conditions of
the
environment
temperature humidity
Operational
environment
10°C to 35°C 20% to 80%, No condensation is allowed.
Guarantee range of
the printing accuracy
15°C to 28°C 40% to 60%, No condensation is allowed.