Specifications
3 Specifications PJ-1614NXE PJ-2216NXE Maintenance Manual
3-8
3.5 Conditions of the installation environment
WARNING
•
••
• Do not install the printer at any of the following places. Doing so may cause
the printer fall and injure people
•
••
• Slanted place
•
••
• Where vibration of other machines is transmitted.
•
••
• Do not sit on the printer or put heavy things on the printer. Doing so may
cause the printer fall and injure people.
•
••
• Do not cover the printer with something like a blanket or a table cloth. That
may cover the ventilation hole, confine the heat inside of the printer and cause
fire.
•
••
• Do not install the printer in a damp or dusty place. Doing so may cause electric
shock or fire.
(1) Conditions of the installation environment
Select the place to install the printer in accordance with "3-1 Conditions of the installation environment".
Table 3-1 Conditions of the installation environment
Installation area
5m
2
or more, 2.6m or more is required for the width
Floor strength of the installation place
2490Pa (300kgf/m
2
) or more
Power
specifications
Voltage AC 100V to 120V±10%
Frequency 50/60Hz±1Hz
Capacity 10A or more
Conditions of
the
environment
temperature humidity
Operational
environment
10°C to 35°C 20% to 80%, No condensation is allowed.
Guarantee range of
the printing accuracy
15°C to 28°C 40% to 60%, No condensation is allowed.
Change rate 2°C or less per hour 5% or less per hour