Specifications
7 Adjustment PJ-1614NXE PJ-2216NXE Maintenance Manual
7-14
7.8 Cover Sensor Adjustment
This section describes the procedure to adjust the cover sensor.
NOTE
Before adjusting the cover sensor, remove the following covers.
• Side cover R: "4.2.1 Removing Side Cover R"
• Side cover L: "4.2.2 Removing Side Cover L"
• Front cover: "4.2.3 Removing Front Cover"
When you have replaced the cover sensor assembly or removed the front cover, always adjust the cover
sensor following the steps below.
1. Start up the self-diagnosis function.
TIP
To learn how to start up and operate the self-diagnosis function, refer to "5 Self-Diagnosis Function".
2. Select "Diagnosis: Sensor" from the Self-diagnosis menu.
3. Select "Inspection: Sensor" from the Inspection menu.
4. Select "Sensor: etc." from the Sensor menu.
5. Verify that the operation panel display "etc.: Cover" changes as follows while opening and closing
the front cover assembly.
6. If the display in the operation panel differs from the front cover status, adjust the sensor cam position.
Table 7-2 Cover Sensor Adjustment
Front cover Display in operation panel
Open Cover: Open
Close Cover: Close