Specifications

PJ-1614NXE PJ-2216NXE Maintenance Manual 5 Self-Diagnosis Function
5-47
5.9.3 Head Up/Down Endurance Menu
This menu performs endurance running for the head up/down operation.
You can perform the capping operation according to your desired settings. The available settings are
shown below.
TIP
If the number of endurance running cycles is set to -1, the heads continuously repeat endurance running until a
key input is given from the operation panel.
The maximum counter value for endurance running cycles is 99999999 (up to 8-digit number). If the number of
cycles exceeds the maximum value, the counter is reset to 0.
The waiting time is not modifiable.
5.9.4 Lever Motor Endurance Menu
This menu performs endurance running for the lever motor.
You can drive the lever motor according to your desired settings.
The available settings are shown below.
Table 5-15 Set Items in Head Up/Down Endurance Menu
Set item Contents Set value Remark
Waiting tim Set the waiting time after one
cycle of endurance running
10 Unit: second
Number of endurance running
cycles
Set the number of endurance
running cycles
-1 to 10000